Tag: Modular 8×8

  • Modular and IR Control

    Modular units have the ability to receive Infra-red(IR) commands in two different ways; Code-based IR and Contextual based IR. Code-based IR uses unique codes for each room/output, whilst Contextual IR uses a single set of codes, with the unit determining where the IR command originated.

    If you wish to revert the unit to Code based IR control please edit the settings.ini file on the SD card (Please use only PC based systems to edit the SD card contents) and remove the following information.

    cir1 = 0x00ff9867
    cir2 = 0x00ffd827
    cir3 = 0x00ff8877
    cir4 = 0x00ffa857

    cir1 = 0x00ff807f
    cir2 = 0x00ff00ff
    cir3 = 0x00ff30cf
    cir4 = 0x00ff906f